ASSY-MSN, ASSY-MSN, PCA POWER CONTROLLER DC INPUT, Spare part - Make
| 1011-3572-000-S | |
| 5821521 | |
| GE HealthCare | |
승인 번호를 입력하고 장바구니에 품목을 추가하도록 제출하십시오. p>
Please enter approval number
OR
승인 번호를 모르십니까? 800-437-1171로 전화하십시오.
처음 세 개의 프롬프트에 opt 1을 입력하고 시스템 ID를 사용할 수 있도록하십시오.
장바구니에 품목을 추가하고
승인 번호, GE는 배송을 위해 주문을 확인하기 전에 연락을 드릴 것입니다.
Select your approver's name and submit to add item(s) to your cart
Please Select Approver Name
OR
Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.
If you add item(s) to cart and submit your order without
selecting an approver, GE will contact you before your order
can be confirmed for shipment.
특색
- High quality Atmel Atmega 103 processor
- Equipped with electronic circuit breaker for protection
- Inbuilt LED Indicator
- RSS-422 interface
제품 개요
The PCA Power Controller DC Input contains supervisory circuitry that performs battery charge control, AC sensing and fan control as well as current, voltage and temperature monitoring. The controller communicates through a RS422, 9.6 kB channel circuit to all the connected devices for their organized functioning. The controller will receive back up power from two 12-volt batteries wired in series. The power controller board contains, the following; AC/DC converter that converts line voltage to high voltage DC, a DC/DC converter that converts high voltage DC to battery voltage and a DC/DC converter that converts battery voltage to 12.5 VDC bus voltage. These are being used in UL Voluson P8, ARC ENTROPY Module, MS CARESCAPE™ Monitor B850, Evaluated/Not Applicable CT, MIC Panda™ Warmer, ARC Airway Gas Module, ARC Aestiva MRI, ARC Aisys, ARC ADU, ARC Avance CS2, ARC Aestiva 7100 and ARC Aespire 7900.
추가 기능
- AAMI approved
- Tested to UL and CSA safety standards
- RoHS compliant
- GSPO
동등 품목:
아래는 동등한 부품에 대한 자세한 정보입니다. 하이퍼 링크가없는 부품은 참조 용으로 만 나열되며 온라인으로 구입할 수 없습니다.
| 동등 품목 | 제품 세부 사항 |
|---|---|
| 5821521 | AISYS-AVANCE POWER UPGRADE KIT |
반품 및 교환
GE Healthcare will accept, for return from customer, items that are in new condition, unworn, unaltered and free of damage. Items cannot be returned or exchanged beyond 30 days from customer’s receipt of the original order and all returned items will be subject to a 15% restocking fee. To obtain a full refund or exchange of the item within the 30 day return period (subject to the 15% restocking fee) customer must request a return materials authorization (RMA) from GE Healthcare and return the item to GE Healthcare utilizing this RMA number. Items must be returned in the original packaging, unused and free of damage.